site stats

Pds-pct-0020 unable to open the powercube

Splet12. avg. 2024 · MiKTeX GPL Ghostscript 9.25: Device 'pdfwrite' requires an output file but no file was specified. **** Unable to open the initial device, quitting. I definitely made sure that the file exists, I tried it using as *.ps file as input, gave the full path, once with and without double-quotes (Windows system), yet nothing worked. SpletSolution Transfer the PowerCube mdc file again from Windows to UNIX. The file was not transferred properly. Steps: 1. Generate the cube again with Transformer 2. Check if this cube works fine for example in PowerPlay Client 3. Transfer this new mdc file from Windows to UNIX. Use the FTP binary mode for the transfer 4.

twt企业IT交流平台 - talkwithtrend,企业IT技术社区,帮助您融入 …

Splet24. nov. 2024 · 3. Turns out you have to go to Project > Info > Configuration and change the following: Share. Improve this answer. Follow. answered Nov 23, 2024 at 23:53. dsynkd. 1,929 4 25 37. 1. Splet22. avg. 2024 · The order of providers for the Web Authentication in IIS. (This may not apply in all environments) Resolution - For the application is IIS, open the "Authentication" feature in "Features View" - Open "Providers" for "Windows Authentication" (right-click or choose the option from the "Actions" pane) - Ensure that "NTLM" is first in the list. asia markt wittenau https://proteuscorporation.com

Error PDS-RM-0002 opening a remote power cube - IBM

Splet30. dec. 2016 · Yes am able to open other pdf file but only password protected files unable to open , i check difrent files Upvote Translate Report Adorobat Adobe Employee , Jan 06, 2024 Could you please try to open any password protected pdf file on desktop version of Reader and see if you are able to open it. Upvote Translate Report Safwan20702 AUTHOR … Splet15. jun. 2024 · Unable to open ((Security)) Cause The user that has been defined in the connection is not part of a user class that has been defined and associated with the cube … asia mart

PDS-PCT-0020 Unable to open the PowerCube: (Open Data …

Category:(cognos高手求救)(TR1901)PDS-PCT-0010 数据高速缓存表或索 …

Tags:Pds-pct-0020 unable to open the powercube

Pds-pct-0020 unable to open the powercube

PDS-PCT-0023 PowerPlay Data Server cannot read data cache

SpletSteps: 1. Open the file located under. 2. Modify/Append the parameter MultiFileCubeThreshold as given below (i.e. less than the number mentioned in pass 5 … Splet1. Generate the cube again with Transformer. 2. Check if this cube works fine for example in PowerPlay Client. 3. Transfer this new mdc file from Windows to UNIX. Use the FTP …

Pds-pct-0020 unable to open the powercube

Did you know?

Splet22. avg. 2024 · - For the application is IIS, open the "Authentication" feature in "Features View" - Open "Providers" for "Windows Authentication" (right-click or choose the option … Splet27. okt. 2024 · Details: PDS-PCT-0020 Unable to open the PowerCube: (Open Data Cache). Cube name or path may be incorrect, cube may be corrupt or may not be a PowerCube. …

Splet详细信息:PDS-PCT-0020 无法打开 PowerCube:(打开数据高速缓存)。 多维数据集名称或路径可能不正确,多维数据集可能已损坏或可能不是 PowerCube 分享 举报 可选中1个或多个下面的关键词,搜索相关资料。 也可直接点“搜索资料”搜索整个问题。 cognos 服务器 数据源 mdc op-err-0068 搜索资料 Splet10. avg. 2024 · But while building the cube, it is writing to only 1 mdp file though it creates many mdp files. The error occurs when that mdp file exceeds the 2GB limit. only 1 mdp file is getting updated and exceeds 2GB. Also i have noticed earlier, cube is not sharing the data equally between the mdps. Please advise. Thanks in advance for your timely help.

SpletOpen the MetricsAuditCube.mdl file found in the Cognos_Transformer_install_path/metricsmodel/ folder with a text editor. Find and delete the line: PackageTimeStamp "/content/folder [@name='IBMConnectionsMetrics']/package [@name='MetricsCubeDS']/model [@name='2012-05-02T02:09:03.848Z']". Save the mdl … SpletPDS-PCT-0020 and TR0162 When Accessing Package Data Source Troubleshooting Problem Error during cube build or creating a new model based on a package or report …

SpletPDS-PCT-0020 Unable to open PowerCube. Using Transformer 10.1.1 to create a cube from a report Studio Report. Originally using a network drive as the location for the cube, I then …

Splet15. avg. 2024 · Unable to connect: We encountered an error while trying to connect to . Details: "We could not register this data source for any gateway instances within this … asia mart seoulSplet02. avg. 2013 · Open the location given in the search result (i.e. C:\Program Files (x86)\Sybase\shared\PowerBuilder) Open another Explorer window and navigate to C:\Windows; Do a search for pb*.dll; For every dll that starts with "pb" or "PB" in the search result, AND is already in the PowerBuilder folder, add a ".bak" extension. i.e. … asiamartSpletPowerCube modules: • VD4 and VM1 series vacuum circuit-breakers • HD4 series gas circuit-breakers • V-Contact series vacuum contactors • service trucks. All the operations of the apparatus are carried out from the front of the module. Degrees of protection The degrees of protection of the PowerCube modules comply with the IEC 60529 ... asia martiniSplet14. feb. 2011 · this can happen if the cube is not on all dispatcher servers. Copy the cube to all the despatcher servers. this solved me once. flag Report Was this post helpful? … asiamatchSplet10. mar. 2015 · Resolving the problem This error means that Transformer can no longer write to the Temporary Cube files. Verify the following - The environment variables TEMP and TMP for System, and User are pointing to a directory on the server with enough space. asia matchSpletPDS-PCT-0020 Unable to open the PowerCube: (Open Data Cache). Cube path/name ma. « on: 03 Nov 2009 03:06:43 am ». Cognos Gurus, I am currently having a major issue … asia materialsSpletPC4820 v1.4 • Installation Manual WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to … asia martin